Filter Results By:

Products

Applications

Manufacturers

Showing results: 316 - 330 of 403 items found.

  • LED Test Programmable DC Electronic Load

    IT8912E Series - I-TECH Electronic Co., Ltd

    IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.

  • Three-Phase Relay Protection Tester

    GDJB-PC - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.GDJB-PC Universal Secondary Injection Relay Test Set is applied to test the relay unit in relay protection system. 2.At the same time GDJB-PC Universal Secondary Injection Relay Test Set could be considered as a universal three phase AC/DC voltage source or current source. 3.It can work alone or connected to computer, inside the relay controller there are new speed digital signal mini PC and real DAC (Digital-to-Analog Converter) template with new high fidelity and high power, the machine has large panel screen and rotating mouse. It is small in volume, high precision.

  • 2000-6000W AC power source

    CX-P2KW - Shenzhen Chuangxin Instruments Co., Ltd.

    The AC power source is made by adopting microcomputer processing chip and high power device. It provides a stable pure sine wave and has voltage, over current, over temperature, overload protection. It can output 0-300V adjustable voltage, and 45-70Hz adjustable frequency as well as fixed frequency as 50 Hz or 60 Hz, 100 Hz and 200 Hz and 400 Hz. This AC power source can simulate power grid of different countries, provide a stable voltage, frequency, waveform which can be used to test and age the exprot products and provide kinds of precision tests for laboratory, measuring room, etc.

  • PXI-2565, 16-Channel, 7 A, SPST PXI Relay Module

    777754-01 - NI

    16-Channel, 7 A, SPST PXI Relay Module—The PXI‑2565 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. It delivers high-current switching of DC power supplies, AC line power, and AC/DC current sources. The PXI‑2565 is fully software programmable and supports multiple instrument synchronization.

  • ZZ Power Booster 1200V/3000V

    ZZ Booster-Transmitter - ZZ Resistivity Imaging Pty. Ltd.

    *3,000W output power in 2 adjustable voltage ranges ( 400V/7.5A, 1,200V/2.5A), the FlashRES booster transmitter is particular useful for surveys in high resistive areas or IP surveys.*When the FlashRES booster transmitter is connected FlashRES-UNIVERSAL, for each current injection, the system could collect 61 voltage measurement, this greatly increases the data collection speed.*Uses two standard 12V batteries connect in series as input power source*The FlashRES booster transmitter is designed for heavy duty usage, the instrument is shock, water and dust proof.*Light-weight and easily mobilised

  • Hall Effect Measurement system

    HMS-3000 - ECOPIA

    Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.

  • High-Density Precision SMU Mainframe (4 Slots, 1U)

    PZ2100A - Keysight Technologies

    The Keysight PZ2100A is the precision source / measure unit (SMU) mainframe that uncompromisingly and densely integrates 20 SMU channels into valuable 1U height, full width, rack space with flexible module options at their best performance. It supports a variety of resources such as the Keysight PZ2110A Precision SMU, PZ2120/21A High-Speed SMUs, and PZ2130/31A High Channel Density SMUs with multiple functions such as pulser and digitizer, as well as precise voltage / current sourcing and measuring to adapt to a wide range of application requirements. The PZ2100A has 4 slots and allows any mixed module configuration for flexible scalability.

  • Materials Test Systems

    Ametek Scientific Instruments

    An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.

  • Laser Spectroscopic Motor Exhaust Gas Analyzer

    MEXA-ONE-QL-NX - HORIBA, Ltd.

    The MEXA-ONE-QL-NX is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.The analyzer combines a light source based on the new quantum cascade technology (efficient lasers in the mid-infrared spectral region) with a precisely adjusted dual path cell to measure low concentrations with maximum sensitivity. The detection limit complies with current European legal requirements.Furthermore, the MEXA-ONE-QL-NX offers wide measuring ranges of up to 5000 ppm (for NO). By using extremely narrowband light sources and measuring under reduced pressure the cross-sensitivity to other exhaust gas components can be drastically minimized.The complete measuring system - including filtration - is specifically developed for the measurement of NH3 and thus guarantees a very fast NH3 rise time (T10-T90) of less than 5 seconds. The MEXA-ONE-QL-NX can be operated as a stand-alone analyzer or integrated into the MEXA-ONE software interface for user-friendly and simplified system operation.

  • Solenoid-Saver

    B-1022-B - ROSS ENGINEERING CORPORATION

    *Solenoid-Saver® eliminates AC hum and reduces heat generation for many types of solenoids.*Controlled application of current prevents coil burnout if high pull-in/low holding current AC or DC solenoids fail to pull-in completely.*Can adapt high pull-in low holding current solenoids to special voltages & frequencies 12V to 250V DC or 12V to 240V AC wideband 25-800Hz.*Optional optical isolated control input 4 to 10V, 5MA, 20 usec or more (or other control voltages) to actuate any high current solenoid directly by computer or other low power signal source.*For coils of 1 ohm to 3,500 ohms DC resistance requiring up to 70 amps during pull-in up to 120 milliseconds. Basic solenoid coil voltage and resistance must be specified.*Eliminates heat producing dropping resistors, bypass switch, dual coils, laminations, & shading coils.*Can increase pull-in and holding force of many types of solenoids.*Optional stored energy to delay solenoid release on loss of power.*Can be used as an added accessory to existing solenoid installation to eliminate AC hum, lower coil temperature and prevent coil burnout.*Optional high speed, 1 microsecond sensing, 1-10 millisecond actuation with stored energy Solenoid-Saver®

  • Mobile Communications DC Source, 15V, 3A

    66311B - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66311B mobile communications DC source provides fast transient, exceptional sourcing, and precision measurement.

  • Source Measure Units

    NGU - Rohde & Schwarz GmbH & Co. KG

    Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.

  • Mobile Comm DC Source w/ Battery Emulation, DVM

    66321D - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66321D mobile communications dc source provides fast transient response, exceptional sourcing, output resistance programming, and precision measurement. This product is specially designed for testing next generation digital wireless communications products. The 66321D mobile communications dc source offers a new capability that simulates the internal resistance of a battery or battery pack. Additionally, these high performance models offer improved transient response and stable output operation with either short or long load leads. The 66321D dc source provides all of the capabilities of the 66321B with the addition of a built-in digital voltmeter.

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2205 - TREK, INC.

    The Trek Model 2205 is a member of Trek’s 2200-series of high-voltage 40 W amplifiers that offesr high performance at an attractive price. It incorporates DC stability, wide bandwidth, well regulated and controlled AC output signals, full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument also stage sinks or sources current into reactive or resistive loads throughout the output voltage range which makes it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

Get Help